Home
International Journal of Science and Research Archive
International, Peer reviewed, Open access Journal ISSN Approved Journal No. 2582-8185

Main navigation

  • Home
    • Journal Information
    • Abstracting and Indexing
    • Editorial Board Members
    • Reviewer Panel
    • Journal Policies
    • IJSRA CrossMark Policy
    • Publication Ethics
    • Instructions for Authors
    • Article processing fee
    • Track Manuscript Status
    • Get Publication Certificate
    • Current Issue
    • Issue in Progress
    • Past Issues
    • Become a Reviewer panel member
    • Join as Editorial Board Member
  • Contact us
  • Downloads

ISSN Approved Journal || eISSN: 2582-8185 || CODEN: IJSRO2 || Impact Factor 8.2 || Google Scholar and CrossRef Indexed

Fast Publication within 48 hours || Low Article Processing Charges || Peer Reviewed and Referred Journal || Free Certificate

Research and review articles are invited for publication in January 2026 (Volume 18, Issue 1)

Comprehensive evaluation of steerable introducer sheaths: Quality control, In-vitro performance, and safety assessment

Breadcrumb

  • Home
  • Comprehensive evaluation of steerable introducer sheaths: Quality control, In-vitro performance, and safety assessment

Kothwala Dr. Deveshkumar Mahendralal, Patel Jayendra Lakshmanbhai and Rathod Akshit Dahyabhai *

Meril Medical innovation Pvt. Ltd., Bilakhia House, Survey No. 135/139, Muktanand Marg, Chala, Vapi - 396 191, Gujarat, India. 

Review Article

International Journal of Science and Research Archive, 2025, 15(02), 526-537

Article DOI: 10.30574/ijsra.2025.15.2.1283

DOI url: https://doi.org/10.30574/ijsra.2025.15.2.1283

Received on 22 March 2025; revised on 30 April 2025; accepted on 03 May 2025

Background: Steerable Introducer Sheaths are pivotal in minimally invasive procedures, yet existing In-vitro testing methods often fail to replicate complex human vasculature adequately, leading to insufficient evaluation of device performance under clinically relevant conditions. Current methodologies lack standardized approaches to simultaneously assess critical parameters such as kink resistance, steerability, and hydrophilic coating durability in anatomy simulation models. This limitation risks incomplete safety and efficacy assessments prior to clinical use.

Objective: The below-stated research reports the requirement for performing an In-vitro simulation test procedure to determine the performance and safety of the device before it can be used in a clinical Studies. This study addresses this gap by developing a novel In-vitro simulation test method using silicone-based anatomy simulation models that mimic human vasculature’s mechanical and geometric complexities. The proposed method aims to comprehensively evaluate device safety and performance, ensuring reliable pre-clinical validation.

Methods: The study utilized an In-vitro anatomy simulation model to assess the performance of the Steerable Introducer Sheath in navigating challenging pathways. A silicone-based anatomical model replicated human vasculature, enabling the evaluation of key parameters such as flexibility, kink resistance, pushability, and the effectiveness of the hydrophilic coating. Post-testing analysis confirmed the structural integrity and durability of the sheath after repeated use. Results demonstrated enhanced maneuverability, reduced procedural time, and improved patient safety, highlighting the sheath's efficiency in minimally invasive procedures that closely represented real anatomical structures, ensuring accurate and reliable performance assessments.

Results: The results exhibited improved maneuverability, strength of the structure, and frictional reduction, confirming the device to negotiate tortuous pathways with less resistance. Accurate fluoroscopic imaging was ensured by the radiopaque markers, and unobstructed introducer sheath passage by the PTFE inner lining. 

Conclusion: The research confirms the Steerable Introducer Sheath to be a very reliable minimally invasive device that improves procedural efficacy and patient safety. The Steerable Introducer Sheath was highly maneuverable, resistant to kinking, and procedurally efficacious during In-vitro examinations. Its hydrophilic coating reduced friction, and radiopaque markers ensured precise placement. The device is useful for minimally invasive procedures by improving catheter control, reducing complications, and optimizing patient outcomes, and it merits further clinical confirmation for broader use.

Steerable Introducer Sheath; Neurovascular procedures; Interventional radiology; Catheterization; Stenosed vasculature; Fenestrations; Frictionless steerability; Cardiac ablation and In-vitro Simulation

https://journalijsra.com/sites/default/files/fulltext_pdf/IJSRA-2025-1283.pdf

Preview Article PDF

Kothwala Dr. Deveshkumar Mahendralal, Patel Jayendra Lakshmanbhai and Rathod Akshit Dahyabhai. Comprehensive evaluation of steerable introducer sheaths: Quality control, In-vitro performance, and safety assessment. International Journal of Science and Research Archive, 2025, 15(02), 526-537. Article DOI: https://doi.org/10.30574/ijsra.2025.15.2.1283.

Copyright © 2025 Author(s) retain the copyright of this article. This article is published under the terms of the Creative Commons Attribution Liscense 4.0

For Authors: Fast Publication of Research and Review Papers


ISSN Approved Journal publication within 48 hrs in minimum fees USD 35, Impact Factor 8.2